Abstract

In 1949, N. F. Mott argued that when free carriers screen a Coulomb centre, the bound state vanishes at a critical density — and the criterion built on that argument, n_c^(1/3) a_H = κ, became the most-used first estimate of a metal–insulator critical density in physics. I credit the argument at full strength: the transition's existence and its suddenness are the paper's permanent return, and the criterion's canonical form organises six named systems on my bench within a factor of about two. What I price is the derivation status of the criterion's constant. The vanishing is argued from the screening picture, not derived from the many-body Hamiltonian, and the constant is an estimate: Mott's own form carries κ ≈ 0.20, the canonical form 0.250000, and the record's inverted form carries estimates of C from 2.0 to 4.2 — κ from 0.500000 down to 0.238095. Because the density goes as the constant's cube, that spread is a factor of 15.625000 in the density the criterion predicts, at every Bohr radius, before any material is named. My bench returns the criterion at every constant of the record's set for six named systems, and inverts each measured pair into the constant that system itself implies: 0.194704 (Si:P), 0.212093 (Si:Bi), 0.220486 (CdS:In), 0.221388 (n-GaAs), 0.267820 (n-InSb), 0.253703 (VO2) — a scatter of 2.602585 in density at fixed radius, and not one of them the canonical 0.250000. Counted plainly: 1 screening criterion carrying 1 estimated constant against 0 derivations in 1949 of the criterion or of its constant. Grade for this census entry, printed at full size: REASON FOUND / STILL TURNING — PREMISE-ONLY, explicitly not a kill and not a falsification. The program headline stands unmoved: vacuum catastrophe NOT SOLVED / PARTIAL, producing-count 0.

Keywords: Mott 1949; metal–insulator transition; screening; Mott criterion; critical density; effective Bohr radius; doped semiconductors.

The result, in plain language

Mott's criterion estimates the metal–insulator critical density from a constant that was never derived; across the record's own constant set the predicted density spreads by a factor of 15.625000, and the six measured systems each imply their own constant — not one of them the canonical 0.250000.

How this paper fits the research program

Paper 817 of the program — a census closure — CC-147, Mott 1949, priced.

The research program — the papers, in order