Sound and communication

Being heard, and hearing: bells, horns, sirens, ear protection, and the distances sound actually carries.

Paper · DOI 10.5281/zenodo.24113821

The Bell's Parish: Audibility Radius, Households Reached, and the Bell Mass at Which a Solar Horn Wins on Cost

The result. A 100 kg bell in a 20 m tower is audible over a radius of 1879.6 m and reaches 133.2 households at USD 52.56 per household (19.03 households per USD 1000, the best of the masses tabulated); a USD 650 solar horn passes the bell on households per unit cost only above a crossover bell mass of 2560 kg. Proven in simulation.

Paper · DOI 10.5281/zenodo.24113886

The Hand-Crank Siren Indoors: One Roof Siren Against Six Corridor Sounders in a Two-Floor School

The result. One roof hand-crank siren reaches the 75 dBA warning criterion in 24 of 32 rooms (quietest room 70.2 dB) at USD 850 and 90 seconds to full level; six corridor sounders (three per floor) reach all 32 rooms (quietest room 77.6 dB) at USD 770 and 5 seconds — 85 seconds sooner. Proven in simulation.

Paper · DOI 10.5281/zenodo.24113695

How Far a Signalling Drum Carries: Range by Terrain, Size and Tension

The result. Reference 0.60 m drum (95 Hz, 100.0 dB at 1 m): maximum range 2.11 km flat open ground, 0.83 km forest, 3.82 km valley; 1.00 m drum reaches 3.57 km flat (1.69x reference); doubled tension shortens flat range to 2.02 km. Proven in simulation.

Paper · DOI 10.5281/zenodo.24113790

What Actually Protects Ears: Real-World Attenuation of Foam Plugs, Cotton Wool, and Cloth Against a Workshop Noise Spectrum

The result. Against a 103.29 dBA workshop spectrum, well-fitted foam plugs give 72.74 dBA (dose 5.9 percent), poorly fitted foam plugs 94.33 dBA (863.3 percent), cotton wool 99.82 dBA (3071.5 percent), and a cloth wrap 100.11 dBA (3283.6 percent); the minimum effective attenuation required is 18.29 dB, or 21.29 dB with a 3 dB margin. Proven in simulation.

Paper · DOI 10.5281/zenodo.24113972

Two Wires Between Houses: Speech Reach, Ring Reach, and the Copper–Steel Sizing Rule for a Magneto Field Telephone

The result. Speech (1000 ohm loop budget) reaches 22.44 km on 1.0 mm copper, 5.89 km on 1.5 mm steel, and 23.56 km on 3.0 mm steel; ring reach is 5.0 times speech reach on every wire; wire costs USD 126.67 per km (1.0 mm copper) against USD 30.52 per km (1.5 mm steel), and steel wins on wire cost within its reach but cannot serve beyond 23.56 km in any gauge tabulated. Proven in simulation.

Paper · DOI 10.5281/zenodo.24114111

Sounding in Fog: The Frequency Band That Carries Across Water, and Why a High-Pitched Boat Whistle Does Not Reach a 600-Metre Crossing

The result. A 124 dB (at 1 m) horn carries 826.0 m in fog at 125 Hz and 739.1 m at 250 Hz but only 178.8 m at 4000 Hz; the band that carries across the stated 600 m crossing is roughly 125 to 500 Hz; bare minimum source 121.0 dB at 1 m at 125 Hz (0.426 m horn mouth), recommended specification a 0.90 m horn at 127.5 dB with a fog range of 1199.9 m; the commonly sold high-pitched boat whistle (4000 Hz, 115 dB at 1 m) reaches only 113.8 m in fog and falls 52.4 dB short of the criterion at the far bank — it does not work as a fog signal for this crossing. Proven in simulation.

Paper · DOI 10.5281/zenodo.24114074

A Household Radio Tree for Emergency Alerts: Hop Range by Terrain, Relay Count, and Time to Alert a Settlement Without a Repeater

The result. Largest hop 7517.8 m flat open ground, 2000.2 m broken/hilly, 1674.2 m forest; for a settlement 8 km across with 503 households the tree needs 0 relay households on flat ground, 18 at depth 2 on broken ground, and 30 at depth 3 in forest, alerting everyone in 45 seconds, 1.5 minutes, and 2.25 minutes respectively; full radio set USD 20102, forest tree total USD 20522 (USD 40.80 per household). Proven in simulation.

Paper · DOI 10.5281/zenodo.24114086

A Low-Power FM Transmitter a Village Can Afford: Coverage by Power and Antenna Height, and the Cost per Listener Reached

The result. 10 W on a 30 m mast covers 10.40 km and reaches 6795 people at USD 0.433 per person reached (station USD 2945.45); 30 W on 45 m reaches 21085 people over 18.32 km at USD 0.212 per person; doubling power multiplies radius by 1.217 while doubling antenna height multiplies it by 1.533, equivalent to multiplying power by 4.50; a 20 W station on a 12-hour broadcast day needs a 146.7 W panel and a 1980.4 Wh battery (solar system USD 939.50). Proven in simulation.

Paper · DOI 10.5281/zenodo.24113761

Being Heard in the Market: How Far a Voice Carries Against Market Noise, What a Day of Shouting Costs, and What a Small Amplifier Changes

The result. At 70 dBA a shout reaches only 1.259 m and at 80 dBA only 0.398 m; conversation at 1.0 m at 80 dBA requires 86.0 dBA, above a maximum sustained shout, with a daily vocal dose of 955.5 normal-voice hour equivalents; a $15.00 amplifier with 12 dB gain cuts the dose by a factor of 15.85. Proven in simulation.

Paper · DOI 10.5281/zenodo.24114016

The Speaking Tube: Useful Length, Bend Allowance, and a Sizing Rule for a Two-Storey Workshop

The result. At normal speech a straight tube serves 21.6 m at 25 mm diameter and 86.3 m at 100 mm, with four bends reducing those reaches to 9.3 m and 37.0 m; on a 10 m, four-bend two-storey workshop run, 25 mm delivers 64.51 dB and does not meet the 65 dB criterion, while 38 mm delivers 66.73 dB and 50 mm delivers 67.76 dB — fit 50 mm, five bends or fewer. Proven in simulation.

Paper · DOI 10.5281/zenodo.24113986

The String Telephone, Priced Honestly: A Level Budget and the Distance at Which Speech Gives Out

The result. Fixed cup coupling losses consume 35.0 dB of the 55.0 dB budget (63.6 percent); the remaining 20.0 dB gives maximum intelligible distances at 10 N tension of 25.0 m on cotton twine, 40.0 m on nylon line, and 80.0 m on taut steel wire. The coupling losses, not the string, set the limit. Proven in simulation.

Paper · DOI 10.5281/zenodo.24114066

The Ultrasonic Pest Repeller, Tested by Arithmetic: A Disproof of the Whole-Room Claim

The result. Representative stated device (100 dB at 1 m, 40 kHz) reaches the generous 80 dB effect criterion only 5.12 m in a clear line of sight and 1.6 m behind furniture; furnished-room coverage under the stated shadowing model is 27.5 percent, and through a wall the level at 3 m is 62.7 dB, below the criterion — the whole-room and whole-house claims do not survive the arithmetic. Proven in simulation.

Paper · DOI 10.5281/zenodo.24113854

Sizing a Village Loudspeaker: Horn, Amplifier, Pole, and Solar Supply for a Market Square

The result. A 25 W amplifier and 104 dB horn on a 6 m pole give a 132.5 m coverage radius against a 75 dBA speech criterion (85.7 dB at a 40 m square edge); the stated schedule needs 82.5 Wh per day, met by a chosen 50 Wp panel and 20 Ah battery; complete system USD 1050; a passive megaphone reaches 9.8 m in the same market noise. Proven in simulation.

Paper · DOI 10.5281/zenodo.24114080

Finding the Water Level by Ear: How Deep a Well an Echo Can Certify, by Stopwatch and by Phone

The result. Stopwatch-by-ear timing error is 34.04 m at every depth and certifies no depth to plus or minus 1.0 m; phone-recording timing gives 0.51 m error at 10 m and 0.58 m at 50 m, and certifies plus or minus 1.0 m down to 59.4 m over calm water (42.0 m rough), at 0 dollars added cost for a phone already owned. Proven in simulation.

Paper · DOI 10.5281/zenodo.24113743

How Much a Whistle or Drum Code Can Say: A Bound on Codebook Size Against Distance

The result. At symbol error bound 0.001 with six-symbol messages (4.0 s each): whistle supports 262144 distinct messages at 500 m, 64 at 1000 m, none at 2000 m, binary limit 1.12 km; drum supports 4096 at 500 m, 64 at 1000 m, binary limit 1.50 km. Proven in simulation.

Paper · DOI 10.5281/zenodo.24113718

The Upwind Shadow: Where Wind Refraction Ends a Horn Signal, and Where to Place the Post

The result. Horn 112 dB at 1 m, free-field range 1.13 km; in a moderate 5 m/s daytime wind: upwind 115 m, crosswind 703 m, downwind 1450 m; dawn inversion restores crosswind to 1130 m but upwind only to 124 m while wind blows; calm dawn restores 1130 m in all directions. Placement rule: post upwind of the settlement so listeners are downwind. Proven in simulation.

Paper · DOI 10.5281/zenodo.24113823

The Grain Mill's Noise Budget: Daily Dose by Task Rotation, and What Distance, a Mud-Brick Enclosure, and a Shorter Rotation Each Buy

The result. Baseline rotation dose 2112.7 percent (time-weighted average 98.25 dBA); distance to 2 m gives 681.8 percent, a 12 dB mud-brick enclosure gives 326.9 percent, and the enclosure plus a rotation of 0.5 hours on each loud machine and 6.5 hours on quiet work gives 87.3 percent at 84.41 dBA; the enclosure costs $156.00 and requires 480 mud bricks. Proven in simulation.

← Back to Solving the World's Problems